Protectol RCW 1000

Industrial Solutions · Coatings

Protectol RCW 1000

Water-based protective coating

Protectol RCW 1000 is a corrosion-resistant clear coating for metals.

  • pH 8–9.5
  • VOC 6% by weight
  • Cleans up with water
4HHARDNESS
ASTM D3363
Item No. Pack size DOT
03720-D5503 55 gal Not regulated
03720-P5004 5 gal Not regulated
03720-C4001 4 × 1 gal Not regulated

Order: 800-752-6627 · sales@kor-chem.com

Category:

Product Information

Description

Protectol RCW 1000 is a corrosion-resistant clear coating for metals. It is a water-based acrylic coating for direct-to-metal application on steel, galvanized steel and aluminum, and it dries to a moderate to low gloss finish with 4H pencil hardness. The film passes ASTM D522 mandrel flexibility and ASTM D1308 resistance to gasoline and paint thinner. Protectol RCW 1000 thins and cleans up with water.

Advantages

Corrosion Resistant

Clear protective coat for metal surfaces

Water-Based

Thins and cleans up with water; 6% VOC

Fluid Resistant

Passes ASTM D1308 gasoline and paint thinner

Hard, Flexible Film

4H hardness; passes ASTM D522 ¼" mandrel

Directions

  1. Mixing: Agitate thoroughly before use. If needed, reduce with water. Keep the lid closed.
  2. All surfaces: Clean, dry and free of oil, grease, dirt, soluble salts and loose material. Test adhesion on the prepared substrate.
  3. Steel: Degrease, then remove rust, mill scale and loose coating by blasting or mechanical preparation. Coat before flash rust develops.
  4. Galvanized steel: Remove oil, zinc salts, white rust and passivation residue; lightly abrade without removing the zinc.
  5. Aluminum: Clean, dry and lightly abrade or pretreat; coat promptly. Use a compatible primer if direct application falls short.
  6. Apply: Apply evenly with a sponge and polish off the excess with a clean towel, or mist on with a fine-mist HPLV sprayer. Test a small area first.
  7. Cure: Begins to cure within 1 hour; full cure in 72 hours. Keep liquids off the surface until cured.
  8. Clean-up: Flush tools and equipment with water after use; ventilate enclosed areas until the coating cures.

Coverage guide

DRY FILM FT² / GAL FT² / 5 GAL PAIL FT² / 55 GAL DRUM
1.0 mil 375 1,875 20,625
2.0 mils 188 940 10,340

Theoretical coverage rate per gallon from the product data; pail and drum figures are calculated from it. Actual coverage depends on surface profile, application method and loss.

Recommended applications

  • Steel
  • Galvanized steel
  • Aluminum
  • Anodized aluminum
  • Direct-to-metal clear coat

Typical characteristics

Property Value
Appearance White, opaque liquid
Finish Moderate to low gloss
Odor Butyl
Resin Acrylic
pH 8–9.5
VOC 6% by weight (as supplied)
Specific Gravity 1.020
Flashpoint Above 200°F (93°C)
Weight, per U.S. gallon 8.5 lbs
Solubility Complete in water
Viscosity (Brookfield #4) 1,500–2,500 cps at 60 rpm
Freezing Point -5 to -10°F
Hardness (ASTM D3363) 4H
Flexibility (ASTM D522) Pass, ¼" mandrel, 180°
Fluid Resistance (ASTM D1308) Pass: gasoline, paint thinner
Clean-up Water

Safety & handling

WARNING May cause respiratory irritation (H335). May cause drowsiness or dizziness (H336). Repeated or prolonged skin contact may cause dermatitis (skin drying).

  • If in eyes: Flush with water for at least 15 minutes, holding eyelids open. Remove contact lenses and keep rinsing. Seek medical attention.
  • If on skin: Wash with soap and water. Launder contaminated clothing before reuse. Seek medical attention if irritation persists.
  • If inhaled: Move to fresh air and keep at rest. Call a poison center or physician if you feel unwell.
  • If swallowed: Do not induce vomiting. Call a physician at once.
  • Eyes: Safety glasses with side shields or splash-proof goggles
  • Hands & body: Chemical-resistant (impervious) gloves; normal materials-handling clothing; boots
  • Breathing: NIOSH-approved protection if the PEL is exceeded or vapors cause irritation
  • Ventilation: Use only outdoors or in a well-ventilated area
  • Shelf life: 1 year minimum at 75°F in the original closed container.
  • Keep from freezing.
  • Lot number: bottom right corner of every label, a Julian date followed by the item number.
  • Keep tightly closed, away from heat, flame and sunlight. Store locked up in a well-ventilated place, away from strong oxidizers, acids, alkalis, chlorine and amines.
  • Disposal: Do not dump into sewers, on the ground or into any waterway. Dispose of contents and container per federal, state and local regulations.
  • Shipping: Not regulated (DOT, IATA, IMDG).

Safety information summarized from the Protectol RCW 1000 Safety Data Sheet. The SDS governs; see it for full precautions.

Registrations & compliance

Item Detail
GHS signal word WARNING
DOT Not regulated (DOT, IATA and IMDG)
VOC 6% by weight, as supplied
Use For industrial use only

Documents

Related products

Made in AtlantaManufactured by Kor-Chem in Atlanta, Georgia.
ISO 9001:2015Quality management certified.
Distributor supportProduct training, wall charts and technical service. Services
Private brandingYour label on our chemistry. Learn more

Go to Top